ALT2BAT · ALTERNATOR-TO-BATTERY CHARGER · VICTRON ORION XS · NMEA 2000

All the amps your alternator can safely give. Not one more.

A fixed-current alternator-to-battery charger either cooks the alternator or leaves output on the table, because the safe ceiling is never constant — higher at cruise on a cool morning, lower at idle in an engine room at 65 °C. Alt2Bat measures the alternator case temperature and runs your Victron Orion XS chargers so the alternator sits at its maximum safe output, whatever the conditions.

Up to 2× Orion XS Temperature regulated Engine-aware NMEA 2000 node Fails safe by design Phone web UI
FEATURES

The controller your Orion XS was missing.

🌡

Temperature-following control

A probe on the alternator case feeds a control loop aimed at a setpoint you choose — 105 °C by default, the accepted marine practice for case temperature. Below the setpoint the current limit climbs; near it, it eases. The loop settles where heat in balances cooling out: the true sustainable output for the present RPM, airflow and ambient.

🔋

Two chargers, one authority

Drives up to two Orion XS 12/12-50 units over VE.Direct using Victron's own External Control mode: a fresh current limit every second, while each Orion keeps its bulk, absorption and float algorithm and its battery preset — LiFePO4 included. The combined target is split between the units by their individual limits.

🚦

Engine-aware

Reads engine RPM and coolant temperature from NMEA 2000 — any engine gateway or ECU that publishes them. At idle the belt is left alone; with cold coolant the ceiling is reduced; with no RPM at all charging is held at 0 A. Boats without engine data run on temperature alone.

📈

Two hours on the graph

Alternator temperature, commanded and measured current and battery voltage, sampled every ten seconds and drawn against clock time on the phone — so you can see the loop find the ceiling on a real motoring leg.

🛠

Orion setup from the box

Each unit's stored settings — absorption and float voltage, engine-shutdown detection, input lockout, current limit — read and edited from the web page. The box captures each unit's configuration as a profile and re-applies it if a unit is ever replaced; one button syncs unit B from unit A.

📶

Self-healing WiFi, self-installing updates

Three saved networks and an open setup access point when none is in range. Firmware updates install themselves only while the engine is off and nothing is charging, and a version that fails to settle rolls back on its own.

HOW IT WORKS

Regulate the case, not the current.

The windings of an alternator run 30–50 °C hotter than its case. Holding the case near 105 °C keeps class F and H insulation well inside its rating — the same principle as a dedicated smart regulator, but using the DC-DC chargers you already have and leaving the alternator's own internal regulator untouched.

🔁

A setpoint loop, not a guess

Below the setpoint the combined limit rises at a rate you set; inside the deadband it holds; above it, it backs off. Proportional and integral gains, deadband and ramp rates are all yours to tune from the phone — with sensible defaults that suit a small marine diesel.

⚖️

Split by each unit's limit

The combined target is shared between the two Orions in proportion to the current limit you give each one, and clamped to it. If one unit drops out, the other takes what it safely can.

Proven on the builder's boat

A 120 A Valeo alternator on a Yanmar 3YM30AE, in a 65 °C engine room. Driven flat out by a fixed-current charger it overheated and tripped, delivering around 48 A effective. Under Alt2Bat it sustains around 70 A at a 105 °C case — hour after hour, with the temperature trace flat.

WIRING

Drops into the wiring you already have.

The heavy cables are the standard Orion XS alternator-to-house layout: both chargers take their input from the starter battery, deliver into the house bank, and are fused at both ends. Alt2Bat adds only light-gauge connections — a VE.Direct cable to each Orion, the probe on the alternator case, the thermal switch, and one NMEA 2000 drop cable that also powers the controller.

Alt2Bat wiring schematic Alternator G1 B+ to starter battery BT1. Orion XS U1 and U2 inputs fused (F1, F2) from the starter battery, outputs fused (F3, F4) to house bank BT2, all negatives to the common negative (ground). Alt2Bat U3, powered from the NMEA 2000 bus: temperature probe RT1 on the alternator case, VE.Direct cable to each Orion, NMEA 2000 drop X1, and an optional VE.Direct cable from its CERBO socket to a customer's Cerbo GX (U4). Normally-closed 130 °C thermal switch S1 on U2's remote terminals (required hardware backstop). F160–70 A F260–70 A F360–70 A F460–70 A +BT1STARTER BATTERY12 V G B+ G1 · ALTERNATOR · internal regulator RT1probe S1NC 130 °Chardware backstop U1ORION XS12/12-50 · unit A IN+ OUT+ IN− OUT− VE.Direct U2ORION XS12/12-50 · unit B IN+ H·L OUT+ IN− OUT− VE.Direct U3ALT2BATalternator charger controller PROBE A B N2K · power + data CERBO U4CERBO GXVictron GX device VE.Direct · optional X1drop cable · powers the controller NMEA 2000 BACKBONEengine gateway · Cerbo GX · chartplotter +BT2HOUSE BANK12 V · LiFePO4 / AGM N1 · alternator B+ = starter battery +house + busbarhouse + busbar DC positive · 16 mm² under 5 m, 25 mm² to 10 m Common negative bus (ground) · all − terminals VE.Direct · standard cable, plug-in at both ends RT1 temperature probe · supplied, always fitted S1 NC thermal switch 130 °C · required hardware backstop NMEA 2000 backbone · X1 drop cable, data and power F1–F4: 60–70 A fuse at the battery end of each Orion cable · the controller is powered from the NMEA 2000 bus, no separate supply
🔌

Heavy DC

Per Orion: one cable from the starter battery to IN+, one from OUT+ to the house bank, each with a 60–70 A fuse at the battery end; 16 mm² under 5 m. Negatives to the common negative bus. The alternator-to-starter-battery cable is never touched.

🔗

Data and probe

One standard VE.Direct cable per Orion, plugged straight into the controller — nothing to strip or solder. The probe bolts to the alternator's rear housing and plugs into the controller. One standard drop cable puts the box on the NMEA 2000 backbone and powers it — no separate supply. A third socket, CERBO, takes an optional VE.Direct cable to the Cerbo GX — the Cerbo then sees the two chargers as one Orion XS.

🌡

Hardware backstop

A normally-closed 130 °C thermal switch on the alternator replaces the wire bridge on Orion B's remote terminals. Above its trip point unit B shuts down by itself, with no software in the loop; Alt2Bat re-normalises onto unit A.

SAFETY

Fails safe, by construction.

The Orion's own one-minute fallback

Alt2Bat only ever sends a volatile current limit. If the box stops talking for a minute — power lost, crashed, unplugged — each charger reverts by itself to the fixed limit stored in its memory. A dead controller can never leave the alternator uncontrolled.

🧯

Sensor fault means zero

An open, shorted or implausible probe reading cuts the combined limit to 0 A immediately, and stays there until the reading is good again. The chargers stay awake and connected throughout.

🔌

Never breaks the charge cable

Every cut-back acts through the Orion's current limit or enable line. The alternator output is never open-circuited under load — no load-dump spike, ever.

🌡

A hardware backstop, always

A normally-closed 130 °C thermal switch on the alternator, wired to unit B's remote terminals, trips above the software setpoint. It works with no software in the loop at all.

🔒

The Orion stays in charge of the battery

Charge voltages, chemistry preset and the engine-shutdown detection live in the Orion, not in the box. Alt2Bat only caps the current; nothing it does can overcharge a bank.

CERBO & PLOTTER

Seen by your Cerbo and your chartplotter.

🧭

A real NMEA 2000 node

Alt2Bat claims its own address on the bus and publishes alternator voltage, current, temperature and charger state as the standard charger PGNs (127508, 127506, 127507, 127750). A Cerbo GX or a chartplotter lists the alternator as a charger — no VE.Direct cable to the Cerbo required.

🚨

Alerts on the bus

Over-temperature, a probe fault and a charger error are raised as standard NMEA 2000 alerts (126983 with 126985 text). A test button on the Setup tab lets you check how your own displays react before you need them to.

🧪

Bus diagnostics built in

CAN error counters by type, the address it claimed, and the state of your engine gateway — how old the last RPM is, whether the gateway is silent or sending "not available", how many fast packets were lost. "No engine data" tells you why.

WEB INTERFACE

Everything from a phone browser.

Status, Graph and Setup tabs at altcharger.local on the boat WiFi — no app. Live alternator temperature and target, each Orion's state, input and output, error code and off-reason; the engine card; and every control parameter editable in place.

Setpoint & deadband Gains & ramp rates Max combined current Per-unit current limits Probe calibration offset Ignore engine data Orion EEPROM editor Orion profiles & sync WiFi networks Port capture for support
📊

Status

Temperature against setpoint, combined target and what each Orion is actually delivering, battery voltage, engine RPM and coolant, WiFi and bus health — refreshed every two seconds.

📈

Graph

The last two hours of temperature, current and voltage on a clock-time axis. Watch warm-up, the approach to the setpoint and the hold.

🎙

Ten-second port capture

One button records the raw traffic on both Orion ports and uploads it for analysis — the fastest way to show us a unit that misbehaves. It can also be requested remotely, so the boat records on its next check-in.

Alt2Bat sets the current limit of Victron Orion XS chargers; it is not a charger itself. Battery protection and the engine-shutdown detection stay configured in the Orion and keep working with the box disconnected.

AT A GLANCE

What's in the box.

Alt2Bat controller Alternator temperature probe

Not included: the Victron Orion XS chargers (one or two) and their VE.Direct cables. Powered from the NMEA 2000 bus: one standard drop cable supplies the controller, brings engine data and puts the charger on the bus.

GET ONE

Interested?

Contact for pricing and availability. Tell us your alternator, engine and which Orion XS units you have or plan to fit.